New Challenges Due to Varying Fly Ash Composition
Regular testing of the fly ash is essential due to varying compositions. It was found that not only the fly ash itself can be potentially flammable, but hydrogen is also formed in the gas phase of the plant – a substance with a high risk of explosion and fire.
Collaboration for a Safe Solution
To ensure the safety of the entire plant, Ragn Sells and AIK turned to their partner KOLB HSW to jointly develop a reliable technical solution.
The AGRU Solution
To prevent spark formation caused by electrostatic charging and to protect plant equipment from fire hazards, the following measures were implemented:
- Four extraction vessels were equiped with new lids, made of AGRU PPs el
- Two vessels were additionally fitted with new scrubbers made of AGRU PPs el
- The entire exhaust air piping system was enlarged and fully executed in AGRU PPs el
The Result
By using AGRU PPs el, the risk of electrostatic spark formation was reduced. At the same time, the entire exhaust system was equipped with a flame-retardant material, making an important contribution to safe and reliable plant operation.